博文

目前显示的是 八月, 2018的博文

Application of the ZBL R660 rebar locator

图片
1.ZBL-R660 Concrete Rebar Scanner Introduction ZBL-R660 is mainly used to test the reinforced concrete structure and is capable cover thickness and rebar diameter on the reinforced concrete surface. 2.ZBL-R660 Concrete Rebar Scanner Features 1. With multi-coil technology, the rebar position can be located more real-time and accurately; 2.Rebar position, spacing and cover thickness are displayed on the same screen 3. USB data transmission 4.Up to 65m for profile and grid scan modes and up to 10m for signal scan mode; 5.Two data view modes: graph and list, which enables convenient and flexible operation as well as quick view of the data; 6.Bluetooth data transmission 7.Five scan modes are provided to suit for different measuring environment 3.ZBL-R660 Concrete Rebar ScannerTechnical Information 4.Detail show of ZBL-R660 Concrete Rebar Scanner 5.ZBL-R660 Concrete Scanner Rebar Scanner Screeen Display 6.ZBL-R660 Concrete Rebar Scanner Application

Details to show the TEM-620X Rebar Detector,rebar locator

图片
1.1Brief Introduction of  TEM-620X Rebar Detector,rebar locator The first generation portable rebar integrated detector TEM-620X uses an electromagnetic induction method, which can detect the rebar location and cover thickness & diameter accurately, store, transfer and analyze the real time test data. The model THA620X is the pinnacle of work with the modern simple design, incorporating the handy & durable features and sophisticated electronic technology. THA620X series rebar detector is mainly used to test the location, distribution, direction, the thickness of rebar and the diameter of cover in concrete structure such as walls,columns, beam-slabs etc. It can also detect the location of pipelines and metal embedded parts. The multiple coil structure design make it more accurate&responsive and higher resolution. 1.2 Application Range of  TEM-620X Rebar Detector,rebar locator (1). Testing the location, distribution, direction, and diameter of the rebar and the t

Made new shipment of HT-225 concrete test hammer for our Indonesia customer

图片
1. Use a grinding stone to smoothen the test surface 2. Perform a few test impacts with the rebound hammer on this smooth, hard surface before taking any measurements which you are going to evaluate. Perform a consistency check on the test anvil 3.Ensure all settings are correctly done. 4 Position the hammer perpendicular to and against the test surface. Push the concrete test hammer adainst the surface at a moderate spped until the impact is triggered. Bes aware that the plunger generates a recoil when it deploys. Therefore it is recommentded to hold the rebound hammer with both hands, perpendicular to the test surface, before triggering the impact. 5. Each test surface should be tested with at least 12 impacts dropping the highest and the lowest and then take the average of the remaining. The individual impact points must be spaced at least 25mm apart. 6. Interpret the test results. 1. Use a grinding stone to smoothen the test surface 2. Perform a few test

electromagnetic flow transmitter into Korean

图片
1.Intoduction of Electromanetic flow meter conveter Electronic flow transmitter is parts of electromagnetic flow meter.According to the size of the sensor, we offer four kinds of transmitter housing, As shown in the figure below, please note: the PCB board, software and menus and functions are be the same, only the size of housing and shape of the housing is different. 2. Technical information of Electromagnetic Flow Converter 3. Electromagnetic Flow Converter Suitable to Size of the (mm) 1,2,3、6、8,10、15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、450、500、600、650,700、800、900、1000、1100,1200、1300,1400、1500,1600、1700,1800、2000、2200、2400、2600、2800、3000 4. Power Supply of Electromagnetic Flow Converter Power supply :85VAC --- 265VAC or or 110VAC to 420VAC or 24VDC or 3.6v lithium battery 5. Details show of the Electromagnetic Flow Converter 6.Dimension of Electromagnetic Flow Converter 7 .Shipment of Electromagnetic Flow Converter 8 .Contact with us

New shipment for the electromagnetic flow transmitter,remote display

图片
1.Intoduction of Electromanetic flow meter conveter Electronic flow transmitter is parts of electromagnetic flow meter.According to the size of the sensor, we offer four kinds of transmitter housing, As shown in the figure below, please note: the PCB board, software and menus and functions are be the same, only the size of housing and shape of the housing is different. 2. Technical information of Electromagnetic Flow Converter 3. Electromagnetic Flow Converter Suitable to Size of the (mm) 1,2,3、6、8,10、15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、450、500、600、650,700、800、900、1000、1100,1200、1300,1400、1500,1600、1700,1800、2000、2200、2400、2600、2800、3000 4. Power Supply of Electromagnetic Flow Converter Power supply :85VAC --- 265VAC or or 110VAC to 420VAC or 24VDC or 3.6v lithium battery 5. Details show of the Electromagnetic Flow Converter 6.Dimension of Electromagnetic Flow Converter 7 .Shipment of Electromagnetic Flow Converter 8 .Contact with us

New shipment for the TDS-100H hand held ultrasonic flow meter

图片
1.Preface of TDS-100H hand held ultrasonic flow meter The TDS-100H ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation.    2.Technical Information of TDS-100H hand held ultrasonic flow meter 3.Details Show of TDS-100H hand held ultrasonic flow meter 4.Transducer of TDS-100H hand held ultrasonic flow meter 5.Transducer show of TDS-100H hand held ultrasonic flow meter 6.Accessories of TDS-100H hand held ultrasonic flow meter 7.Application show of TDS-100H hand held ultrasonic flow meter 7.Our Factory and shipment 8.Contact with us